35
diallEr - PrOgrammiNg
D. Prog
neSS D24 Control Panel - inStallation & PrograMMing Manual
OPTION No DESCRIPTION
DEFAULT
P750E
P751E
P752E
P753E
ADMIN Area client code
AREA 1client code
AREA 2client code
AREA 3client code
0000
0000
0000
0000
arEa CliENT COdES
these options are for programming individual client codes for each area. option
P60e 3e must also be on.
P750e
admin area client code.
P751e
area 1 client code.
P752e
area 2 client
code.
P753e
area 3 client code.
P750e–P753e
prOgraM MOde leVel:
Installer, Remote by PC
FaCtOrY deFault:
0000
tO prOgraM:
p
[
75
x]
e
[Client Code]
e
related OptIOns:
P60E 3E, Send Open/Close with Client Codes
as per P75xE
OPTION No DESCRIPTION
DEFAULT
P82E
ENABLE OPTIONS
Enable Dialler
[not used]
Enable Radio Interface
Enable Output Expander
2E
1E
3E
4E
ON
ENablE OPTiONS
P82e 1e:
not used
P82e 2e: eNAbLe tHe DIALLer.
(on by default). this option can be used to disable the dialler while retaining all
dialler programming.
P82e 3e: eNAbLe rADIo INterfACe.
(off by default).
enables the optional 100-200 radio interface, (if used).
P82e 4e: eNAbLe oUtPUt exPANDer.
(off by default).
enables the optional 100-011 output expander, (if used).
the optional D24 output expander connects to the D24 control panel and
provides 35 open collector outputs and 1 relay output.
the outputs can be used to drive mimic displays, provide additional outputs on
alarm and various other custom purposes.
the output expander board interfaces with the D24 by three wire serial
connection. the board is designed to fit inside the D24 control panel housing.
P82e
prOgraM MOde leVel:
Installer, Remote by PC
FaCtOrY deFault:
2E on: Dialler enabled
3E off: Radio Interface disabled
4E off: Output Expander disabled
tO prOgraM:
p82e
[Select option]
e
P80e, P81e
CreAte INStALLer DefINeD oUtPUt groUPS - metHoD 2
See page 25
for full details of output expander operation, see page 52.
heX aCCOunt nuMBer
if the Client account
numbers are required to be
sent in hex, use this table
when programming.
(hex a cannot be used).
Hex keypad
keypad
DIgIt
keY Display
B
VieW
11
C
arM 12
D
Monitor
13
e
area
14
F eXCluDe
15
Содержание D24
Страница 1: ...Installation Programming MANUAL D 24 Control Panel and Dialler REV 1 9 ...
Страница 53: ...53 Ness D24 Control panel Installation Programming Manual Notes ...
Страница 59: ...59 Ness D24 Control panel Installation Programming Manual Notes ...
Страница 60: ...This page is intentionally blank ...