7
neSS D24 Control Panel - inStallation & PrograMMing Manual
NESS D24
NESS D24
NESS D24
0V
ALARM
TAMPER
N.C.
N.C.
+12V
N.C.
N.C.
0V
ALARM
TAMPER
N.C.
N.C.
+12V
N.C.
N.C.
0V
ALARM
TAMPER
N.C.
N.C.
+12V
N.C.
N.C.
NESS QUANTUM DETECTOR
(all models)
NESS QUANTUM DETECTOR
(all models)
NESS QUANTUM DETECTOR
(all models)
Any zone
1-24
Any zone
1-24
Any zone
1-24
Zone
Zone
TAMP
0V
C
C
C
+12V
Zone
Zone
TAMP
0V
C
C
C
+12V
Zone
Zone
TAMP
0V
C
C
C
+12V
DETECTORS - 4 WIRE CONNECTION, NO TAMPER
SIREN WIRING
DETECTORS - 4 WIRE CONNECTION WITH ZONE TAMPER
DETECTORS - 6 WIRE CONNECTION, WITH TAMPER
NESS D24
TAMP
C
EXTERNAL
INTERNAL
TAMP
C
ALTERNATIVE 12V SIRENS:
100-172 Ness 12V Internal Siren
100-238 Top Hat 12V Piezo Screamer
RED
RED
BLACK
BLACK
N.O. TAMPER SWITCH
(761-002) Colour: BLACK
N.C. TAMPER SWITCH
(SWI920) Colour: WHITE
ALTERNATIVE TAMPER SWITCH WIRING
For N.C. Tamper Switches
STROBE LIGHT
(NOI300)
The terminal block should
be mounted inside the
siren cover.
HORN
SPEAKER
(NOI110)
2K2
2K2
WIRING EXAMPLES
4K7
2K2
2K2
2K2
4K7
2K2
RESET
STROBE
SRN A
SRN B
SRN +
RESET +
ZONE TAMPER DISABLED
ZONE TAMPER ENABLED
When Zone Tamper is enabled, the zones are sealed with
two 4K7 resistors which allow monitoring of both
Alarm and Tamper on each zone input over 4 wires.
Zone Tamper looks for these resistances:
When Zone Tamper is enabled, (P34E 6E = off), then
all zones must be wired as shown above, otherwise zone
alarms will be interpreted as tamper alarms.
ZONE SEALED: 2K2
ZONE ALARM: 4K7
TAMPER ALARM: OPEN CIRCUIT
NOTE:
P34E 6E is ON
P34E 6E is OFF