46
O P E r a T i O N
oP
neSS D24 Control Panel - inStallation & PrograMMing Manual
viEw mENu
the VieW menu can be used at any time to display the status of Zone, tamper,
System and Power inputs.
the status of these inputs can be displayed “live” as it happens, or as a previous
event in Memory mode.
to VIeW A CUrreNt ALArm:
Press...
,
the MeMory icon will be on
and one of the system icons
ZONE
TAMPER
T
SYSTEM
POWER
along with a number to indicate
which alarm is present. if there is no current outstanding alarm, pressing VieW
from the normal zone display mode will display the last event.
to VIeW tHe StAtUS of ALL ALArmS:
Press...
[repeat presses]
repeated presses of the VieW button will cycle viewing of Zone, tamper, System,
Power and Memory sub-menus.
or, each sub-menu can be directly viewed by pressing
[1–6]
DefAULt VIeW
the display always shows the
zone menu by default.
it will automatically revert back
to the Zone menu after eight
seconds if left in any other view
menu.
to VIeW ZoNeS
ZONE
Press...
the zone indicators 1–24 will show the state of the 24 zones and possibly one or more other
icons flashing to indicate other alarms.
to VIeW tAmPerS
TAMPER
T
Press...
Zone indicators will show the state of the four tamper inputs:
tAmPer 1:
external tamper alarm.
tAmPer 2:
Control Panel tamper alarm.
tAmPer 3:
Zone input tamper alarm.
tAmPer 5:
radio interface tamper alarm.
to VIeW SYStem
SYSTEM
Press...
Zone indicators will show the state of the eight System inputs:
SYStem 1:
Keyswitch Panic
SYStem 2:
Dialler line fault
SYStem 3:
Keypad connection fault
SYStem 4:
Control panel fault
SYStem 5:
Duress alarm
SYStem 6:
Panic alarm
SYStem 7:
Medical alarm
SYStem 8:
user Code alarm
SYStem 9:
access to installer Program mode
to VIeW PoWer
POWER
Press...
Zone indicators will show the state of the six Power alarms:
PoWer 1:
Mains power failure
PoWer 2:
Control panel backup battery is low
PoWer 3:
DC supply failure
PoWer 4:
Zone reference power failure
PoWer 9:
radio device battery low. (Zone indicators 1–8 will show which device)
PoWer 0:
radio Key battery low. (Zone indicators 1–8 will show which radio Key)
This is the normal display while disarmed
with no outstanding alarms. The ZONE icon
is on as well as any number 1 to 24 if zones
are being unsealed.
Tamper numbers will be on only if there
are Tamper alarms to view.
Zone numbers will be on only if there are
unsealed zones or alarmed zones to view.
System numbers will be on only if there
are System alarms to view.
Power numbers will be on only if there are
Power alarms to view.
Содержание D24
Страница 1: ...Installation Programming MANUAL D 24 Control Panel and Dialler REV 1 9 ...
Страница 53: ...53 Ness D24 Control panel Installation Programming Manual Notes ...
Страница 59: ...59 Ness D24 Control panel Installation Programming Manual Notes ...
Страница 60: ...This page is intentionally blank ...