19
P r O g r a m m i N g
Prog
neSS D24 Control Panel - inStallation & PrograMMing Manual
arEa ParTiTiONiNg
deFInItIOn
area Partitioning allows the 24 zones to be split into 4 partitions; areas 1, 2, 3 and
administrator (admin) area.
By default, all zones are assigned to the admin area. When there are no zones
assigned to areas, a full arm or Disarm turns the admin area on and off.
COMMOn area ZOnes
Zones assigned to more than one area are armed only when all the assigned
areas are armed.
Common area Zones will automatically arm only when
all
the assigned areas are
armed. Common area Zones will automatically Disarm when
any
of the assigned
areas Disarms.
OperatIOn
operation depends on the type of user code being used.
area operation only applies to zones when they are in the armed state. this
means that Day, 24hr and Monitor zones are independent of the area operations.
note: area partitioning is in addition and separate to Monitor Mode.
aSSigNiNg ZONES TO arEaS
P310e
assign zones to administrator area
When a zone is assigned to the admin area it is automatically removed from all
other areas.
* P310e is used only to
add
zones to the admin area. When a zone is assigned to
any other area it is automatically removed from the admin area.
P311e
assign or remove zones from area 1
P312e
assign or remove zones from area 2
P313e
assign or remove zones from area 3
P310e – P313e
prOgraM MOde leVel:
Installer, Remote by PC
FaCtOrY deFault:
All zones assigned to Admin area.
tO prOgraM:
p
[
31
x]
e
[Zone No]
e
*
Toggles the option ON and OFF.
nOtes:
• If no Area operation is required, assign all
zones to the Admin area (P310E).
OPTION No
DESCRIPTION
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Zones
P310E
P311E
P312E
P313E
P321E
P322E
Assign zones to ADMIN AREA
Assign zones to AREA 1
Assign zones to AREA 2
Assign zones to AREA 3
Assign zones to MONITOR 1
Assign zones to MONITOR 2
ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
ON
Factory default settings shown
aSSigNiNg mONiTOr ZONES
Monitor mode allows partial arming of the system - eg., for night-time perimeter
protection.
if also using area Partitioning, assign area 1 zones to Monitor 1 and area 2 zones
to Monitor 2.
P321e
assign zones to Monitor 1
P322e
assign zones to Monitor 2
P321e – P322e
prOgraM MOde leVel:
Installer, Remote by PC
FaCtOrY deFault:
No monitor zones.
tO prOgraM:
p
[
32
x]
e
[Zone No]
e
Toggles the option ON and OFF.
nOtes: