30
diallEr - PrOgrammiNg
D. Prog
neSS D24 Control Panel - inStallation & PrograMMing Manual
rEmOTE aCCESS OPTiONS
these options will enable the D24 to auto answer an incoming call and carry out
the functions as described.
See reMote oPeration By telePhone, page 51.
P58e
prOgraM MOde leVel:
Installer, Remote by PC
FaCtOrY deFault:
none
tO prOgraM:
p58e
[Select option]
e
OPTION No DESCRIPTION
DEFAULT
P59E
Required Rings to Auto-answer
1
ON
Enable upload/download with Callback
Enable upload/download with Fax Defeat
Enable remote ADMIN Arming
Send O/C reports with Client codes
as per P75xxE
Send only ADMIN AREA O/C reports
Enable Open/Close reports
Enable remote AREA 1 Arming
Disable Open/Close reports
Enable remote AREA 2 Arming
Enable remote AREA 3 Arming
Enable remote toggle AUX1 & AUX2
Enable remote Disarm all Areas
P58E
P60E
REMOTE ACCESS
OPTIONS
OPEN/CLOSE
REPORTING OPTIONS
1E
1E
2E
2E
3E
3E
4E
4E
5E
6E
7E
8E
rEQuirEd riNgS TO auTO-aNSwEr
this option sets the number of double rings before the D24 enables auto-
answering of the next call.
the number of rings can be set from 0 to 20 rings. 1 ring is recommended for fax
defeat to work correctly.
FaX deFeat
Fax Defeat works as follows:
1. Phone the D24 telephone number and listen for the required number of rings
(ring ring...ring ring) and then hang up.
2. Call the number again within 60 seconds.
3. the dialler will answer the very next incoming call on the first ring detected (this
may require one or two rings in practice).
if 60 seconds has expired before the next call, the dialler will revert back to the
count-ring mode as above.
P59e
prOgraM MOde leVel:
Installer, Remote by PC
FaCtOrY deFault:
1 ring
tO prOgraM:
p59e
[required rings]
e
(Select 0 to 20 rings)
OPEN/ClOSE rEPOrTiNg OPTiONS
P60e 1e eNAbLe oPeN/CLoSe rePortS
P60e 2e SeND oNLY ADmIN AreA oPeN/CLoSe rePortS
P60e 3e SeND o/C rePortS WItH CLIeNt CoDeS AS Per P75xxe
this option enables the reporting of area open/close reports using the Client
numbers as programmed at options P751e, P752e, P753e.
P60e 4e DISAbLe oPeN/CLoSe rePortS
When this option is enabled, option 1e automatically disables.
if open/Close reports are disabled, the panel will send a ForCeD oPening
rePort if there has been an alarm during the armed period.
P60e
prOgraM MOde leVel:
Installer, Remote by PC
FaCtOrY deFault:
1E on: Open/Close reports enabled
tO prOgraM:
p60e
[Select option]
e
Содержание D24