23
P r O g r a m m i N g
Prog
neSS D24 Control Panel - inStallation & PrograMMing Manual
maP alarmS TO OuTPuT grOuPS
these options set the output groups which various system alarms will trigger
when alarmed.
P39xxe mAP tAmPer ALArmS
P39
[output group 0–31]
e
[tamper alarm number]
e
P40xxe mAP SYStem ALArmS
P40
[output group 0–31]
e
[System alarm number]
e
P41xxe mAP PoWer ALArmS
P41
[output group 0–31]
e
[Power alarm number]
e
P42xxe mAP geNerAL PUrPoSe tImer
P42
[output group 0–31]
e 1e
P39xxe – P42xxe
prOgraM MOde leVel:
Installer, Remote by PC
FaCtOrY deFault:
[see table]
tO prOgraM:
p
[Option No]
e
[Output Group]
e
[Alarm No]
e
Maps alarms to the selected output group.
nOtes:
• Alarms can be disabled by mapping them to
Output group 0.
• Alarms are removed from an output group by
mapping them to a different output group.
• To use the KEY input as a keyswitch input,
program p400e 1e
, (this maps the input to
Output Group zero, which disables it as a
zone).
eXaMple:
To make zones 23 & 24 into 24hr zones by
mapping them to output group 17.
P3817e 23e 24e
External Tamper
Control Panel Tamper
Zone input Tamper
Radio Interface Tamper
Mains power failure
General Purpose Timer
Backup Battery low
DC supply failed
Zone reference supply failed
Radio Device battery low
Radio Key battery low
Keyswitch Panic (KEY input)
Dialler line fault
Keypad connection fault
Control Panel fault
Duress alarm
Panic alarm
Medical alarm
Radio Supervision Alarm
RK4 Radio Key Aux button
User Code alarm
OPTION No DESCRIPTION
DEFAULT
GROUP
P39xxE
P40xxE
Map
to output groups
TAMPER ALARMS
Map
to output groups
SYSTEM ALARMS
1E
1E
27
22
27
24
27
24
27
24
29
27
30
30
27
2E
2E
3E
3E
5E
4E
5E
6E
7E
9E
0E
8E
P41xxE
P42xxE
Map
to output groups
POWER ALARMS
Map
to output groups
GENERAL PURPOSE
TIMER
1E
1E
30
0
30
23
23
30
30
2E
3E
4E
9E
0E
Choose an Output Group (0-31)
Turn ON the alarms required to be in the selected Output Group
Note:
xx refers to the output group number, (can be either one or
two digits) See the output groups table on page 24.