24
P r O g r a m m i N g
Prog
neSS D24 Control Panel - inStallation & PrograMMing Manual
1 2 3
16
4
17
5
18
6
19
7
20
8
21
9
22
10
23
11
24
12
25
13
26
14
27
15
28 29 30 31
Any combination of
OUTPUTS can be
combined to make an
OUTPUT GROUP
FACTORY DEFINED
OUTPUT GROUPS
OUTPUTS
SIREN A
SIREN B
RESET
STROBE
AUX 1
AUX 2 (Relay)
SONALERT
FIRE
SIREN A Burst
RESET Burst
PRE-ALARM Sonalert
DIALLER
TIMER
ALARM STATE
SIREN TONE 1
SIREN TONE 2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
INSTALLER DEFINED
0
Zones or alarms mapped to Output Group
0 will be disabled
MEDICAL
oUtPUt groUPS table
OuTPuTS, dEfiNEd
the D24 has 16 individual outputs which can be mapped, through output groups,
to various alarms.
1.
Siren a: Siren driver output for connecting a maximum of 3 x 8 ohm horn speakers.
2.
Siren B: Second siren output with the same specifications as Siren a.
3.
reSet: 12V DC output for connecting ness Sirens, piezo sirens, etc.
4.
StroBe: latched 12VDC output for connecting strobe lights.
5.
auX 1: the auX output is a programmable open Collector output suitable for leDs,
relays, etc.
6.
auX 2 relay: Dry changeover contacts, (n.C. CoM. n.o.) with a contact rating of 2a @
24V.
7.
Sonalert: Beeps all keypads when activated.
8.
Fire: Fire indicator icon on all keypads.
9.
Siren a BurSt: Siren a output burst for 2 seconds.
10.
reSet BurSt: reset output burst for 1 second.
11.
Pre-alarm Sonalert:
• Sonalert beeps on all keypads when an input turns on.
• Pre-alarm time is equal to entry delay. Siren A bursts at the end of Pre-Alarm if panel
reset has not cancelled it.
• The sonalert is turned off upon panel reset.
12.
Dialler: reports alarms by dialler when the mapped input alarms.
13.
tiMer: Programmable general purpose timer
14.
alarM State:
• If selected, alarm indicators fast flash when any input assigned to the output turns on.
the alarm clears only when the panel is reset by entering a code.
• If not selected, outputs follow the inputs and alarm indicators turn on steady when the
input is on.
15.
Siren tone 1:
16.
Siren tone 2:
what are Output grOups?
output groups are different
combinations of the 16 available
outputs. any type of alarm can
be mapped to an output group.
the use of output groups
simplifies the mapping of
outputs to inputs.
For example, by mapping a
zone to output group 17, the
zone will trigger these outputs:
Siren a & Siren B (Siren
tone 1), reSet, StroBe anD
Dialler.
output groups 1–15 are blank
by default and can be defined
by the installer.
output groups 16–31 are
factory defined with commonly
used combinations of outputs.
any zone or alarm can be
disabled by mapping it to
output group 0.
what are Outputs?
outputs are physical or virtual
outputs such as Siren outputs,
the Strobe output, the Dialler
etc.