neSS D24 Control Panel - inStallation & PrograMMing Manual
OPTION No
DESCRIPTION
DEFAULT
P93E
Medical Delay
0 hours
mEdiCal dElay
any 24 hour zone or Key switch input or Panic input may be used to control
Medical alarm by assigning the chosen input to output group 16.
A.
instant Medical alarm: immediately sound the sirens and send a Medical alarm
report to the Central Monitoring Station. (the Medical alarm Delay must be set at
zero hours).
b.
inactivity Medical alarm: the Medical alarm is reported if the Medical alarm
button is not pressed within the pre-programmed Medical alarm Delay. (the
Medical alarm Delay can be set between 1 and 48 hours).
INStANt meDICAL ALArm - oPerAtIoN
1. if the Medical alarm Delay is not being used, simply press the designated
Medical alarm button.
2. if the Medical alarm Delay is being used, an instant Medical alarm can be sent
by pressing the button twice within 12 seconds. on the first press, the keypad/s
will beep once per second during the 12 second period. on the second press, the
keypad/s will beep fast to indicate that the Medical alarm has been reported.
INACtIVItY meDICAL ALArm - oPerAtIoN
the inactivity Medical alarm can be used to summon assistance if a person has
become incapacitated and is not able to press their Medical alarm button.
For example, if the Medical alarm Delay is set for 24 hours, the Medical alarm will
be triggered if the button is not pressed every 24 hours.
When 20 minutes of the Medical alarm Delay time remains, and the Medical
alarm button has not been pressed, the keypad/s will beep for 10 seconds as a
reminder.
as a final warning that the Medical alarm delay is due to expire, the keypad/s will
beep continuously during the final 10 minutes.
P93e
prOgraM MOde leVel:
Installer, Remote by PC
FaCtOrY deFault:
0 hours (disabled)
tO prOgraM:
p86e
[0-48 hours]
e
related OptIOns:
P40xxE 7E To map the Medical Alarm to an
Output Group. Default is Output Group 30
(So dialler). See page 23.
Medical Alarm Operation, page 45.