background image

 

 

 

 

Anthem MDX Crestron Module

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
Revision:

20190412 

Date:

2019/04/12 

Author(s):

Richard Mullins 

 

Содержание MDX Crestron

Страница 1: ...Anthem MDX Crestron Module Revision 20190412 Date 2019 04 12 Author s Richard Mullins ...

Страница 2: ...ted digital 5 GetStatus digital 5 ZonePower 1 8 digital 5 ZoneMute 1 8 digital 5 ZoneSource 1 8 analog 6 ZoneVolume 1 8 analog 6 Rx string 6 Feedback Signals 7 TCP_Connect digital 7 PowerFB 1 8 digital 7 MuteFB 1 8 digital 7 FanSpeed analog 7 DeviceName string 7 Tx string 8 SourceFB 1 8 analog 8 VolumeFB 1 8 analog 8 VolumeFB string 8 ZoneName string 8 2 ...

Страница 3: ...feedback The module will provide immediate feedback for changes to most status items as well as polling for everything else at a user definable rate Installation The zip file that included this documentation has the simpl module that needs to be copied in to your project folder The files were built and tested on a Crestron 3 series processor The zip file also contains a SIMPL project and a VT Pro ...

Страница 4: ...mmunication you will need to include a TCP Client The default port is 14999 RS 232 Connection For RS 232 communication you will need to configure the serial settings for a baud rate of 19200 with 8 data bits 1 stop bit and no parity The connection cable needs to be a straight through type cable and can be either 3 wire or fully wired 4 ...

Страница 5: ...y takes effect if the connection type is set to TCP GetStatus digital This signal is used to refresh the current state of the MDX rather than wait for the next polling period ZonePower 1 8 digital Raising this signal will power the matching zone on lowering it will power the matching zone off The signals from 5 8 are designed to be commented out if you are using the MDX 8 ZoneMute 1 8 digital Rais...

Страница 6: ...red on the MDX 8 6 Analog Input 6 ignored on the MDX 8 7 Analog Input 7 ignored on the MDX 8 8 Analog Input 8 ignored on the MDX 8 9 Digital Input 1 ignored on the MDX 8 10 Digital Input 2 ignored on the MDX 8 11 Digital Input 3 ignored on the MDX 8 12 Digital Input 4 ignored on the MDX 8 ZoneVolume 1 8 analog This signal can be set from 0 to 100 to set the matching volume Rx string The data from ...

Страница 7: ...gnal will be high when the mute is active for the matching zone low when the matching zone is inactive The signals from 5 8 are designed to be commented out if you are using the MDX 8 FanSpeed analog This signal will provide the current fan speed in RPM DeviceName string This signal outputs the device name of the connected MDX device SerialNumber string This signal indicates serial number of the c...

Страница 8: ...using the MDX 8 VolumeFB 1 8 analog This signal will provide the current volume as a percentage 0 100 for the matching zone The signals from 5 8 are designed to be commented out if you are using the MDX 8 VolumeFB string This signal provides the volume as a string 0 0 100 0 for the matching zone The signals from 5 8 are designed to be commented out if you are using the MDX 8 ZoneName string This s...

Отзывы: