28
diallEr - PrOgrammiNg
D. Prog
neSS D24 Control Panel - inStallation & PrograMMing Manual
OPTION No DESCRIPTION
DEFAULT
P54E
REPORTING FORMAT
1E
Audible Voice format
Contact ID
2E
3E
ON
rEPOrTiNg fOrmaT
P54e 2e AUDIbLe VoICe formAt
audible Voice format for reporting alarms to any telephone or mobile phone. the
audible voice message repeats the word "alarM".
the person receiving the call can then acknowledge the alarm by pressing the
key on their telephone. Press the
key for at least 2 seconds during pauses in
the audible message.
Open/Close reports and Excluded Zone reports are automatically disabled when
Audible Format is enabled.
Audible Voice format is available in D24 V1.5 and later.
P54e 3e CoNtACt ID formAt
Contact iD format is used for reporting alarms to the central station.
P54e
prOgraM MOde leVel:
Installer, Remote by PC
FaCtOrY deFault:
Contact ID format
tO prOgraM:
p54e
[Select option]
e
See page 58 for the full list of Contact ID reporting codes.