12
P r O g r a m m i N g
Prog
neSS D24 Control Panel - inStallation & PrograMMing Manual
QuiCK STarT PrOgrammiNg
frOm POwEr-uP
the D24 comes programmed with factory default values that should suit most
average installations.
the steps below will show you how to program the Master Code (user Code 1)
and the Client Code and telephone number for central station monitoring.
the installation must be complete - all zones wired and sealed, tampers
connected, keypad wired.
ProgrammIng seqUence:
to enter Installer Program mode
Power up the panel with the J1 link removed, or with the box lid open if using the Tamper Lead Assembly.
(See Main Board Wiring Diagram, page 6).
The PROGRAM light will be flashing
to program the master code
Example Master Code is 1234.
2
2
1
1
1
4
4
P
3
3
E
E
E
P1E is the option for
the Master Code
Press
Enter the new Master Code
followed by E
Enter the new Master Code again
followed by E
to program the dialler client code
Example Client Code is 9876.
The keypad display will flash out the new code.
to program the central station telephone number
Example telephone number is 1234 7890.
2
8
5
1
1
7
4
0
P
3
9
E
E
P51E is the option for
Telephone Number 1
Press
Enter the new telephone number followed by E
The keypad display will flash out the new telephone number.
to exit Installer Program mode
The PROGRAM light will turn off.
tHe PANeL IS NoW ProgrAmmeD AS foLLoWS:
Master Code:.....................
1234
..........................................example only
Dialler Client Code: ...........
9876
..........................................example only
1
telephone number: ...........
1234 7890
................................example only
1
Dialler reporting format .....
Contact ID
...............................Factory default
Zone 1 ...............................
Delay / Dialler /Sirens
...........Factory default
Zone 2 ...............................
Handover / Dialler /Sirens
....Factory default
Zones 3–24........................
Instant / Dialler /Sirens
.........Factory default
entry Delay time ...............
20 seconds
.............................Factory default
exit Delay time .................
60 seconds
.............................Factory default
Siren reset time ...............
10 minutes
..............................Factory default
1
the client code and telephone numbers are normally allocated by the central
station.