16
P r O g r a m m i N g
Prog
neSS D24 Control Panel - inStallation & PrograMMing Manual
ZONE aSSigNmENT
each zone can be assigned with attributes which determine how the zone will be
used.
p19e
Security Delay can be assigned to zones already assigned to more than one area,
(Common area Zones).When a Common area Zone is assigned as a Security
Delay Zone, the zone is armed as soon as any area it belongs to is armed.
(unlike normal Common area Zones, which are armed only when
all
assigned
areas are armed).
p20e
instant zones do not have entry Delay.
p21e
entry Delay Zones operate only in the armed state. these zones will activate the
entry Delay timer (P17e) when they are triggered. if the panel is not Disarmed
before the expiry of the entry Delay timer, the programmed alarm outputs will be
activated.
p22e
handover zones are delayed only if entry is made through an entry Delay zone
first. if a handover zone is triggered first, the zone behaves as an instant zone.
normally, the “point of entry” zone should be Delay zone, with any other zones in
the entry path programmed as handover zones.
p23e
Secondary Delay Zones have an entry delay time eqivalent to the exit Delay time
(P18e).
p271e
Single trigger is the default for all zones. the zone alarms on each single trigger.
p272e
Zones programmed to Double trigger will recognise an alarm condition if:
• The Double Trigger zone has been triggered twice within a 4 minute period.
• If any 2 Double Trigger zones, each trigger once.
• A Double Trigger zone is left unsealed for longer than 15 seconds.
Double trigger is suitable for zones with devices such as Pirs which self reset.
P19e – P272e
prOgraM MOde leVel:
Installer, Remote by PC
FaCtOrY deFault:
see table
tO prOgraM:
p
[Option No]
e
[Zone No]
e
Turns the option ON for each zone selected.
nOtes:
• Selecting a zone attribute will turn off any other
attribute within the same Selection Group.
related OptIOns:
P441E Zones With No Exit Delay, page 26
SELECTION
GROUP
Only one
option is
selectable
per zone
SELECTION
GROUP
OPTION No DESCRIPTION
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Zones
P19E
Security delay zones
P20E
Instant zones
P21E
Entry Delay zones
P22E
Handover zones
P23E
Secondary delay zones
P271E
Single trigger zones
P272E
Double trigger zones
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Factory default settings shown