17
P r O g r a m m i N g
Prog
neSS D24 Control Panel - inStallation & PrograMMing Manual
ZONE iNPuT rESPONSE TimE
p251e–p258e
the input response time can be adjusted for each zone. the factory default is
440ms. this option does not normally need to be adjusted.
this option is not related to Vibration Sensitivity.
Zones are allocated to one sensitivity level at any one time. turning a zone on in
a sensitivity level, turns the zone oFF in any other sensitivity level.
P251e – P258e
prOgraM MOde leVel:
Installer, Remote by PC
FaCtOrY deFault:
P254E: All zones, Normal Sensitivity
tO prOgraM:
p
[Option No]
e
[Zone No]
e
Turns the option ON for each zone selected.
SELECTION
GROUP
Only one
option is
selectable
per zone
OPTION No
TIME (milliseconds)
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Zones
P251E
100
P252E
200
P253E
400
P254E
440 (Normal)
P255E
480
P256E
520
P257E
560
P258E
600
ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
Factory default settings shown
SELECTION
GROUP
Only one
option is
selectable
per zone
OPTION No
PULSES within 600ms
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Zones
P261E
1
P262E
2
P263E
3
P264E
5
P265E
10
P266E
15
P267E
20
P268E
25
HIGHEST SENSITIVITY
LOWEST SENSITIVITY
Factory default settings shown
vibraTiON SENSiTiviTy
p261e–p268e
each zone has individually adjustable sensitivity for connection of nessensor
Vibration Sensors. Vibration Sensitivity counts pulses at 20ms intervals for a time
window of 600ms.
there are 8 levels of vibration sensitivity. P261e is the most sensitive setting.
P268e is the least sensitive setting. (avoid using highest and lowest sensitivity
– they are provided as a guide to the upper and lower limits).
P261e – P268e
prOgraM MOde leVel:
Installer, Remote by PC
FaCtOrY deFault:
no zones selected
tO prOgraM:
p
[
26
x]
e
[Zone No]
e
Turns the option ON for each zone selected.
nOtes:
• Zones are allocated to one sensitivity level
at any one time. Turning a zone ON in a
sensitivity level, turns the zone OFF in any
other sensitivity level.
usIng nessensOrs.
Nessensors are sensitive to high frequencies and
insensitive to low frequencies. Therefore it is not
necessary to apply much force to the protected
structure, rather a very rapid succession of
blows.
The sensitivity has been correctly adjusted when
a single blow applied with a soft object (e.g. by
hand) does not cause an alarm whereas a rapid
series of blows (using a metal object such as a
screwdriver blade) will cause an alarm.
M
H
L
L
RED
YELLOW
N/C Vibration
contacts
N/C Tamper
loop
BLUE
GREEN
36mm
51mm
20mm
16.5mm
350mm cable
2 x
at 27mm spacing
3mm holes
adjUstment
In addition to zone sensitivity
adjustment, the overall
sensitivity of the Nesssensor
can be adjusted by rotating the
body of the Nesssensor within
its bracket.
the bracket must always be
mounted horizontally and the
arrow must point up for the
required setting.
Ness NESSENSOR Vibration sensor
Part No. VIB100
For efficient operation, Nessensors must be attached
to fixtures using screws,
not
adhesive tape or silicone.
Содержание D24
Страница 1: ...Installation Programming MANUAL D 24 Control Panel and Dialler REV 1 9 ...
Страница 53: ...53 Ness D24 Control panel Installation Programming Manual Notes ...
Страница 59: ...59 Ness D24 Control panel Installation Programming Manual Notes ...
Страница 60: ...This page is intentionally blank ...