O P E r a T i O N
oP
neSS D24 Control Panel - inStallation & PrograMMing Manual
EXCludiNg ZONES
Zones and other inputs can be excluded so that it does not generate alarms.
eXCluDe is a method of temporarily disabling an input.
When zones have been excluded, the eXCluDe icon flashes continuously while the
panel is Disarmed and also when armed.
Zones can only be excluded when the panel is Disarmed.
Zone exclude is
not permanent
. excluded zones are automatically inCluDeD next
time the panel is Disarmed.
Zones can be manually included by the same method as excluding. in exclude
mode, simply use the
[NUmber]
sequence to turn oFF the zone lights to be
included.
to enter exclUde mode
Press...
[COde]
...or
(If Shortcut exclude is enabled)
to exclUde zones
(
EXCLUDE
and
ZONE
will be on) Press...
[ZOne nuMBer]
[ZOne nuMBer]
...etc
The selected Zone numbers will turn on.
to exclUde tamPer alarms
Press...
(
EXCLUDE
and
TAMPER
T
will be on)
[taMper nuMBer]
...etc
The selected Tamper numbers will turn on.
to exclUde system alarms
Press...
(
EXCLUDE
and
SYSTEM
will be on)
[sYsteM nuMBer]
...etc
The selected System numbers will turn on.
to exclUde Power alarms
Press...
(
EXCLUDE
and
POWER
will be on)
[pOwer nuMBer]
...etc
The selected Power numbers will turn on.
to exIt exclUde mode
Press...
(
EXCLUDE
will flash while Disarmed and Armed)