P r O g r a m m i N g
Prog
neSS D24 Control Panel - inStallation & PrograMMing Manual
CrEaTiNg iNSTallEr-dEfiNEd OuTPuT grOuPS
mETHOd 1
there are two methods for building your own output groups.
Method 1 uses the option
P43uue yye, yye...etc
to add outputs when building
output groups 1–15.
uu
= output group 1–15,
yy
= output 1–16 (select 1e–16e)
this method should only be used by experienced installers as it provides no visual
feedback when programming.
tO prOgraM:
P43
[Select an output group 1–15]
e
[Select outputs 1–16]
e ...
eXaMple:
to build output group 1 to include the outputs: output 1: Siren a,
output 3: reset, output 12: Dialler
P43 1e 1e 3e 12e
mETHOd 2
Method 2 provides a visual display of the outputs added to the selected output
group but uses 2 separate program options to add the 16 possible outputs to an
output group.
P80 uue yye
uu
= output group 1–15,
yy
= output 1–10 (select 1e–10e)
P81 uue yye
uu
= output group 1–15,
yy
= output 11–16 (select 1e–6e)
tO prOgraM:
P80
[Select an output group 1–15]
e
[Select outputs 1–10]
e ...
P81
[Select an output group 1–15]
e
[Select outputs 9–16]
e ...
eXaMple:
to build output group 1 to include the outputs: Siren a (output 1),
reset (output 3), Dialler (output 12).
P80 1e 1e 3e P81 1e 2e
P43xxe
prOgraM MOde leVel:
Installer, Remote by PC
FaCtOrY deFault:
[see table]
tO prOgraM:
p43
[Output Group 1–15]
e
[Output 1–16]
e
Maps alarms to the selected output group.
nOtes:
• This method does not provide visual feedback
when programming.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
OUTPUT GROUPS
Output
P80xxE
Method 2
P43xxE
Method 1
P81xxE
SIREN A
SIREN B
RESET
STROBE
AUX 1
AUX 2 (Relay)
SONALERT
FIRE
SIREN A Burst
RESET Burst
PRE-ALARM Sonalert
DIALLER
TIMER
ALARM STATE
SIREN TONE 1
SIREN TONE 2
1
1E
1E
1E
2
2E
2E
2E
3
3E
3E
3E
4
4E
4E
4E
5
5E
5E
5E
6
6E
6E
6E
7
7E
7E
8
8E
8E
9
9E
9E
10
10E
10E
11E
12E
13E
14E
15E
16E
11
12
13
14
15
16
INSTALLER DEFINED
P80xxe, P81xxe
prOgraM MOde leVel:
Installer, Remote by PC
FaCtOrY deFault:
[see table]
tO prOgraM:
p80
[Output Group 1–15]
e
[Output 1–10]
e
p81
[Output Group 1–15]
e
[Output 9–16]
e
Maps alarms to the selected output group.
nOtes:
• This method provides visual feedback when
programming.
Содержание D24
Страница 1: ...Installation Programming MANUAL D 24 Control Panel and Dialler REV 1 9 ...
Страница 53: ...53 Ness D24 Control panel Installation Programming Manual Notes ...
Страница 59: ...59 Ness D24 Control panel Installation Programming Manual Notes ...
Страница 60: ...This page is intentionally blank ...