mEdiCal alarm
your system may have been setup with a Medical alarm. this type of alarm can be
used to summon assistance for the elderly or infirm who are living alone. a Medical
alarm is most effective if the system is monitored by a Central Monitoring Station.
Medical alarms can be used in two ways:
1. inStant MeDiCal alarM: immediately sound the sirens and send a Medical
alarm report to the Central Monitoring Station. (in this case, the Medical alarm Delay
is set at zero hours).
2. inaCtiVity MeDiCal alarM: the Medical alarm is reported if the Medical alarm
button is not pressed within the pre-programmed
Medical Alarm Delay.
(in this case,
the Medical alarm Delay is set between 1 and 24 hours).
Instant medIcal alarm
oPeratIon
1. if the Medical alarm Delay is not being used, simply press the designated Medical
alarm button.
2. if the Medical alarm Delay
is
being used, an instant Medical alarm can be sent by
pressing the button twice within 12 seconds. on the first press, the keypad/s will beep
once per second during the 12 second period. on the second press, the keypad/s
will beep fast to indicate that the Medical alarm has been reported.
InactIvIty medIcal alarm
oPeratIon
the inactivity Medical alarm can be used to summon assistance if a person has
become incapacitated and is not able to press their Medical alarm button.
For example, if the Medical alarm Delay is set for 24 hours, the Medical alarm will
be triggered if the button is not pressed every 24 hours. (effectively, it is an, “i’m
oK”, button).
When 20 minutes of the Medical alarm Delay time remains, and the Medical
alarm button has
not
been pressed, the keypad/s will beep for 10 seconds as a
reminder.
as a final warning that the Medical alarm delay is due to expire, the keypad/s will
beep continuously during the final 10 minutes.
medIcal alarm bUtton
the Medical alarm button can be setup to take the place of the keypad Panic button
or it may be a separate button. this must be determined by your installer.
Medical alarm is number
7
in the
SYSTEM
view.
firE alarm
your system may have smoke detectors connected to 24 hour Fire inputs.
Fire inputs, (if enabled), are indicated by the Fire
icon on the keypad.
any zone can be become a Fire input by mapping it to output group 26.
this page is an extract from the
D24 user Manual.
See Page 39 for Medical Delay
programming.
Note:
if inactivity Medical alarm is
enabled, the client should
give notice to their monitoring
station if they plan to be
absent from the premises for
extended periods, (holidays,
visits etc).
Содержание D24
Страница 1: ...Installation Programming MANUAL D 24 Control Panel and Dialler REV 1 9 ...
Страница 53: ...53 Ness D24 Control panel Installation Programming Manual Notes ...
Страница 59: ...59 Ness D24 Control panel Installation Programming Manual Notes ...
Страница 60: ...This page is intentionally blank ...