![background image](http://html.mh-extra.com/html/nec/univerge-neax-2000-ips/univerge-neax-2000-ips_installation-manual_251421454.webp)
– 438 –
NWA-008841-001 Rev.5.0
90ch3003.fm
Switch Settings
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SENSE
(Rotary SW)
NOTE 1
4-F
Set the switch to match the AP Number (04-31) to be
set by CM05.
0-3
Not used
MB (Toggle SW)
NOTE 2
UP
For make-busy
For normal operation
SW2 (Piano SW)
1
ON
Remote loopback (No.0 Circuit)
Normal operation
2
ON
Remote loopback (No.1 Circuit)
Normal operation
3
Not used
4
Not used
5
Not used
6
Not used (Always set to OFF)
7
Not used
8
ON
AP No. 04-15
OFF
AP No. 20-31
Continued on next page
F
4
AP No.
SW4-8: ON
04 05 06 07 08 09 10 11 12 13 14 15
SW4-8: OFF
20 21 22 23 24 25 26 27 28 29 30 31
SW No.
4
5
6
7
8
9
A
B
C
D
E
F
ON
DOWN
OFF
ON
5
6
7
8
1
2
3
4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
NOVEMBER/15/2006
PN-2ILCC (ILC)
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008841 001 ISSUE 5 0 Installation Procedure Manual ...
Страница 24: ... 8 NWA 008841 001 Rev 5 0 90ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 76: ... 60 NWA 008841 001 Rev 5 0 90ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 106: ...CHAPTER 2 INSTALLATION 90 NWA 008841 001 Rev 5 0 90ch2001 fm 5 REMOVE FRONT COVER INSTALLATION OF MAIN EQUIPMENT ...
Страница 148: ...CHAPTER 2 INSTALLATION 132 NWA 008841 001 Rev 5 0 90ch2001 fm Internal Battery Mounting TIE WRAP BATTERY CONNECTION ...