Switch Settings
NOTE 1:
Set the groove on the switch to the desired position.
NOTE 2:
Only when executing “MP Program Download (Local download)” using MATWorX, set the
SW3 to 5-8.
Continued on next page
CAUTION
When the operating power is being supplied to this circuit card, do not plug/unplug this circuit
card into/from its mounting slot.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SW3 (Rotary SW)
NOTE 1
0-F
On Line
(Call processing is in progress)
2
Off Line (Call processing is stopped)
• I/O port: As per CM40 Y=08
3
Off Line (Call processing is stopped)
• I/O port: 9600 bps (Fixed)
4
Debug Mode
(For collecting control signals between
MP and SIP cards)
5
NOTE 2
Off Line (Call processing is stopped)
• I/O port: 9600 bps
6
NOTE 2
Off Line (Call processing is stopped)
• I/O port: 19200 bps
7
NOTE 2
Off Line (Call processing is stopped)
• I/O port: 38400 bps
8
NOTE 2
Off Line (Call processing is stopped)
• I/O port: 57600 bps
B
For clearing the office data
C
For setting the resident system program
1, 9
A, D-F
Not used
0
0
JULY/1/2006
PN-CP24-A/PN-CP24-B/PN-CP24-C/PN-CP24-D (MP)
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008841 001 ISSUE 5 0 Installation Procedure Manual ...
Страница 24: ... 8 NWA 008841 001 Rev 5 0 90ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 76: ... 60 NWA 008841 001 Rev 5 0 90ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 106: ...CHAPTER 2 INSTALLATION 90 NWA 008841 001 Rev 5 0 90ch2001 fm 5 REMOVE FRONT COVER INSTALLATION OF MAIN EQUIPMENT ...
Страница 148: ...CHAPTER 2 INSTALLATION 132 NWA 008841 001 Rev 5 0 90ch2001 fm Internal Battery Mounting TIE WRAP BATTERY CONNECTION ...