– 324 –
NWA-008841-001 Rev.5.0
90ch3003.fm
SW2 (Dip SW)
1
NOTE 3
ON
Sets No. 3 Port forcibly in a state which
DSR signal is always provided.
OFF
Receives DSR signal from the DCE on
No. 3 Port.
2
ON
Enables the receive clock from the DCE
(Modem) when No. 1 Port is synchro-
nous. (Clock is received at the RXC ter-
minal)
OFF
• Uses internal clock as the receive
clock when No. 1 Port is synchro-
nous.
• When No. 1 Port is asynchronous.
3
ON
Enables transmit clock from the DCE
(Modem) when No. 1 Port is synchro-
nous. (Clock is received at the TXC (2)
terminal.)
OFF
• Uses internal clock as the send clock
when No. 1 Port is synchronous.
• When No. 1 Port is asynchronous.
4
ON
Transmit the send clock from the DTE
(this card) when No. 1 Port is synchro-
nous. (Clock is transmitted from the
TXC (1) terminal)
OFF
• Not transmit the send clock from the
DTE (this card) when No. 1 Port is
synchronous.
• When No. 1 Port is asynchronous.
5
ON
When No. 1 Port is asynchronous.
OFF
When No. 1 Port is synchronous.
Continued on next page
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
1 2 3 4 5 6 7 8
ON
PN-AP00-B (AP00)
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008841 001 ISSUE 5 0 Installation Procedure Manual ...
Страница 24: ... 8 NWA 008841 001 Rev 5 0 90ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 76: ... 60 NWA 008841 001 Rev 5 0 90ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 106: ...CHAPTER 2 INSTALLATION 90 NWA 008841 001 Rev 5 0 90ch2001 fm 5 REMOVE FRONT COVER INSTALLATION OF MAIN EQUIPMENT ...
Страница 148: ...CHAPTER 2 INSTALLATION 132 NWA 008841 001 Rev 5 0 90ch2001 fm Internal Battery Mounting TIE WRAP BATTERY CONNECTION ...