– 284 –
NWA-008841-001 Rev.5.0
90ch2002.fm
CHAPTER 2 INSTALLATION
Service Conditions
(1) Date and time for system clock must be set by CM02.
The system clock is updated hourly from the active MP card to the stand by MP card.
(2) The MP0 and MP1 cards must have the same configuration.
• The same software version must be provided to the MP0 and MP1 cards.
• When one MP card mounts the ETHER card, another MP card must mount the ETHER card.
• The same type of Key FD data must be loaded to the MP0 and MP1 cards.
You must prepare two Key FDs per each Key FD function and load the Key FD data to the MP0
and MP1 cards respectively.
(3) Automatic office data copy from the active MP card to the stand by MP card can be executed once
to four times a day by CM43 Y=4>00-03.
(4) The Day/Night mode change in each tenant is updated every two hours from the active MP card to
the stand by MP card.
(5) The MAT and OAI terminal that are connected to the system are available after MP cards changeover
occurs. But, the D
term
IPs that are connected via Virtual IPT or router to the system are not available
for a several minutes until the APR table is updated.
(6) When MP cards changeover occurs while copying the office data from the active MP card to the
stand by MP card, the office data that has been copied is cancelled and the office data copy cannot
be executed.
(7) When MP cards changeover occurs while executing the system data backup of the stand by MP card,
the MP cards changeover will be executed after executing system data backup.
(8) When MP cards changeover occurs, the D
term
IP with protected login mode requires the login
operation again.
(9) While copying the office data from the active MP card to the stand by MP card, saving/loading/
verifying of the office data and the AP program downloading cannot be executed from the MAT.
An error message is indicated on the MAT.
(10) While saving/loading/verifying of the office data and executing the AP program download from the
MAT, the office data cannot be copied from the active MP card to the stand by MP card.
(11) Peg count data and fault information can be taken over the stand by MP card from the active MP card
after MP cards changeover occurs.
BACKUP CPU SYSTEM
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008841 001 ISSUE 5 0 Installation Procedure Manual ...
Страница 24: ... 8 NWA 008841 001 Rev 5 0 90ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 76: ... 60 NWA 008841 001 Rev 5 0 90ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 106: ...CHAPTER 2 INSTALLATION 90 NWA 008841 001 Rev 5 0 90ch2001 fm 5 REMOVE FRONT COVER INSTALLATION OF MAIN EQUIPMENT ...
Страница 148: ...CHAPTER 2 INSTALLATION 132 NWA 008841 001 Rev 5 0 90ch2001 fm Internal Battery Mounting TIE WRAP BATTERY CONNECTION ...