Lamp Indications
Switch Settings
LAMP
NAME
COLOR
FUNCTION
RUN
Green
Flashes at 120 IPM while this card is operating normally.
CRC
Red
Remains lit when detecting Cyclic Redundancy Checking (CRC) errors.
PCM
Red
Remains lit when detecting PCM signal loss.
FRM
Red
Remains lit when detecting Frame Alignment signal loss.
RMT
Red
Remains lit when receiving Frame Alignment signal loss alarm from a
distant office.
AIS
Red
Remains lit when a pattern of consecutive “1” is received. The distant
office transmits this signal for a loopback test.
BL
Red
B channel status
ON
: More than 10 channels are busy
OFF
: All channels are idle
Flash (60 IPM)
: Only one channel is busy
Flash (120 IPM) : 2 through 10 channels are busy
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SENSE
(Rotary SW)
NOTE 1
0-3
Not used
4-F
Set the switch to match the AP Number (04-31) to be
set by CM05.
MB (Toggle SW)
NOTE 2
UP
For make-busy
For normal operation
Continued on next page
F
4
AP No.
SW1-4: ON
04 05 06 07 08 09 10 11 12 13 14 15
SW1-4: OFF
20 21 22 23 24 25 26 27 28 29 30 31
SW No.
4
5
6
7
8
9
A
B
C
D
E
F
ON
DOWN
PN-24DTA-C (DTI)
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008841 001 ISSUE 5 0 Installation Procedure Manual ...
Страница 24: ... 8 NWA 008841 001 Rev 5 0 90ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 76: ... 60 NWA 008841 001 Rev 5 0 90ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 106: ...CHAPTER 2 INSTALLATION 90 NWA 008841 001 Rev 5 0 90ch2001 fm 5 REMOVE FRONT COVER INSTALLATION OF MAIN EQUIPMENT ...
Страница 148: ...CHAPTER 2 INSTALLATION 132 NWA 008841 001 Rev 5 0 90ch2001 fm Internal Battery Mounting TIE WRAP BATTERY CONNECTION ...