CHAPTER 2 INSTALLATION
– 167 –
NWA-008841-001 Rev.5.0
90ch2001.fm
MDF Cross Connections
This table shows the cross connections on the MDF for LTC0 - LTC3.
LTC0 - LTC3 MDF Cross Connection
NOTE 1:
PIN No.46, 21 to 49, 24 on LTC3 cannot be used.
NOTE 2:
PIN No.46, 21 to 49, 24 on LTC2 and LTC3 cannot be used.
NOTE 3:
For the Digital Trunk Interface card, use the different LTC connector from the analog line/trunk
card. The digital line should be separated from the analog line.
Continued on next page
PIN
RUNNING
CABLE
STATION
CABLE
SLOTS
TYPE OF INTERFACE
CO
LDT
2-W
E&M
4-W
E&M
DID
SLT
8COT 4COT 4LDT 2LDT 2ODT 4ODT 2ODT 4ODT 4DIT 2DIT 8LC 4LC LLC
26
WH-BL
GN
1
T0
T0
T0
T0
T0
T0 TxT0 TxT0 T0 T0 T0 T0 T0
1
BL-WH
RD
R0
R0
R0
R0
R0
R0 TxR0 TxR0 R0 R0 R0 R0 R0
27
WH-OR
BK
T1
T1
T1
T1
RcvT0 RcvT0 T1 T1 T1 T1 T1
2
OR-WH
YL
R1
R1
R1
R1
RcvR0 RcvR0 R1 R1 R1 R1 R1
28
WH-GN
GN
T2
T2
T2
T2
T1 TxT1 TxT1 T2
T2 T2 T2
3
GN-WH
RD
R2
R2
R2
R2
R1 TxR1 TxR1 R2
R2 R2 R2
29
WH-BR
BK
T3
T3
T3
RcvT1 RcvT1 T3
T3 T3 T3
4
BR-WH
YL
R3
R3
R3
RcvR1 RcvR1 R3
R3 R3 R3
30
WH-SL
GN
T4
T2
TxT2
T4
5
SL-WH
RD
R4
R2
TxR2
R4
31
RD-BL
BK
T5
RcvT2
T5
6
BL-RD
YL
R5
RcvR2
R5
32
RD-OR
GN
T6
T3
TxT3
T6
7
OR-RD
RD
R6
R3
TxR3
R6
33
RD-GN
BK
T7
RcvT3
T7
8
GN-RD
YL
R7
RcvR3
R7
NOTE 1
TERMINATION OF CABLES ON MDF
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008841 001 ISSUE 5 0 Installation Procedure Manual ...
Страница 24: ... 8 NWA 008841 001 Rev 5 0 90ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 76: ... 60 NWA 008841 001 Rev 5 0 90ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 106: ...CHAPTER 2 INSTALLATION 90 NWA 008841 001 Rev 5 0 90ch2001 fm 5 REMOVE FRONT COVER INSTALLATION OF MAIN EQUIPMENT ...
Страница 148: ...CHAPTER 2 INSTALLATION 132 NWA 008841 001 Rev 5 0 90ch2001 fm Internal Battery Mounting TIE WRAP BATTERY CONNECTION ...