CHAPTER 1 GENERAL INFORMATION
– 47 –
NWA-008841-001 Rev.5.0
90ch1001.fm
Mountable Slots According to Number of Ports
The PIM can mount 8-port or 16-port circuit cards.
Available slots are defined by the number of ports of the circuit card.
*
In slot 08-11, 8-port circuit cards are not mountable. The number of physical ports which can be
provided by slot 08-11 depends on the number of ports of the circuit cards mounted in slot 04-07.
NOTE 1:
For Backup CPU system, the circuit cards are mounted in slot 08 to 10.
NOTE 2:
When PN-4LLCB (LLC) is used for controlling message waiting lamp, the card is to be mounted
in the LT00-LT07 (When PN-4LLCB is not used for controlling message waiting lamp, the card
can be mounted in the LT00-LT11.).
MOUNTING CIRCUIT
CARDS IN SLOT04-07
MOUNTABLE CIRCUIT CARDS IN SLOT08-11
NOTE 1
8-port circuit cards such as;
PN-8COT, PN-8DLC,
PN-8LC, PN-4DAT,
PN-CFTB, PN-2CSI
16-port circuit card;
PN-4CSI
Any application processor cards
4-port circuit cards
NOTE 2
4-port line/trunk cards or any application processor cards
00
01
02
03
04
05
06
07
08
09
10
11
12
P
F
T
V
M
8-port or 16-port circuit cards are mountable
4-port circuit cards are mountable
See below.*
MOUNTING CONDITIONS OF CIRCUIT CARDS
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008841 001 ISSUE 5 0 Installation Procedure Manual ...
Страница 24: ... 8 NWA 008841 001 Rev 5 0 90ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 76: ... 60 NWA 008841 001 Rev 5 0 90ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 106: ...CHAPTER 2 INSTALLATION 90 NWA 008841 001 Rev 5 0 90ch2001 fm 5 REMOVE FRONT COVER INSTALLATION OF MAIN EQUIPMENT ...
Страница 148: ...CHAPTER 2 INSTALLATION 132 NWA 008841 001 Rev 5 0 90ch2001 fm Internal Battery Mounting TIE WRAP BATTERY CONNECTION ...