– 318 –
NWA-008841-001 Rev.5.0
90ch3002.fm
Switch Settings
The figure in the SWITCH NAME column and the position of
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
CAUTION
When the operating power is being supplied to this circuit card, do not plug/unplug this circuit
card into/from its mounting slot.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SW
ON
For turning DC power and the battery
on
OFF
For turning DC power and the battery
off
SW1 (Piano Key SW)
1
ON
CR Voltage: 75 Vrms
OFF
CR Voltage: 90 Vrms
2
ON
Frequency: 20 Hz
OFF
Frequency: 25 Hz
OFF
ON
ON
OFF
1
2
PZ-PW135 (PWR)