– 600 –
NWA-008841-001 Rev.5.0
90ch3004.fm
Switch Settings
• CPU Board
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SW1
(Rotary SW)
0-F
0
Reset of the VM03 card
1
Power ON of the VM03 card
For normal operation
2-E
Not used
SW2
(Push SW)
Push when starting up the VM03 card,
after the SW1 switch is set to 1 and the
SW5 switch is set to DOWN (MB off)
position.
SW3
(Piano Key SW)
1
Not used
2
Not used
SW4
(Piano Key SW)
1
COM2 is used for internal modem
(remote maintenance)
OFF
COM2 is used for RS-232C port (local
direct connection to maintenance con-
sole)
2
Not used
F
2
1
OFF
ON
OFF
OFF
2
1
OFF
ON
ON
OFF
PZ-VM03-M (VM03)