– 466 –
NWA-008841-001 Rev.5.0
90ch3003.fm
Switch Settings
NOTE 1:
Set the groove on the switch to the desired position.
NOTE 2:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the
circuit card.
NOTE 3:
When accommodating the CIR card (PN-4RSTC-A) on Remote site, be sure to set SENSE switch
of all the CIR cards to AP Number 15. Also, set AP Number to any one between 64 and 93 by
CM05 for each CIR card. If a different site is used to accommodate the CIR card, be sure to set
SENSE switch to switch No. 15.
[Series 3800 software or later required]
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SENSE
(Rotary SW)
NOTE 1
NOTE 3
4-F
Set the switch to match the AP Number (04-15) to be
set by CM05.
0-3
Not used
MB (Toggle SW)
NOTE 2
UP
For make-busy
For normal operation
SW1
(Piano Key SW)
1
ON
For make-busy No. 0 circuit
For normal operation
2
ON
For make-busy No. 1 circuit
For normal operation
3
ON
For make-busy No. 2 circuit
For normal operation
4
ON
For make-busy No. 3 circuit
For normal operation
JP0
For normal operation
F
4
AP No.
04 05 06 07 08 09 10 11 12 13 14 15
SW No.
4
5
6
7
8
9
A
B
C
D
E
F
ON
DOWN
4
3
2
1
OFF
ON
OFF
OFF
OFF
OFF
(Jumper pin)
RIGHT
NOVEMBER/15/2006
PN-4RSTC/PN-4RSTC-A (CIR)
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008841 001 ISSUE 5 0 Installation Procedure Manual ...
Страница 24: ... 8 NWA 008841 001 Rev 5 0 90ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 76: ... 60 NWA 008841 001 Rev 5 0 90ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 106: ...CHAPTER 2 INSTALLATION 90 NWA 008841 001 Rev 5 0 90ch2001 fm 5 REMOVE FRONT COVER INSTALLATION OF MAIN EQUIPMENT ...
Страница 148: ...CHAPTER 2 INSTALLATION 132 NWA 008841 001 Rev 5 0 90ch2001 fm Internal Battery Mounting TIE WRAP BATTERY CONNECTION ...