– 179 –
NWA-008841-001 Rev.5.0
90ch2002.fm
• 2W E&M Trunk (PN-2ODT)
When connecting the E and M, make the installation cable by using the connector attached with the
PN-2ODT card.
NOTE:
Both No. 0 and No. 1 circuits must be set to same purpose (2-wire or 4-wire) in one PN-2ODT
card.
MDF Cross Connection for 2W E&M Trunk Card
Continued on next page
1
26
3
28
R0
T0
R2
T2
MDF
LEN001 (No. 1)
LEN000 (No. 0)
PIM0
PN-2ODT
LT00
LEN001 (No. 1)
1
26
3
28
(M)
TO TIE LINE
J
P
LTC0
LEN000 (No. 0)
CN1
08
07
06
05
04
M1
03
E1
02
M0
01
E0
(E)
(Ring)
(Tip)
J
INSTALLATION CABLE
2
1
Tie Line Trunk (LDT/ODT)