– 287 –
NWA-008841-001 Rev.5.0
90ch2002.fm
CHAPTER 2 INSTALLATION
MP System Changeover
• Automatic Changeover
By detecting the emergency notice (EMA), the system executes the changeover from the MP0 to the
MP1 or from the MP1 to the MP0 automatically.
• Manual Changeover
There are two ways for manual changeover as follows.
Case1
By MB Switch Setting:
Flip the MB switch on the MP0 card to ON (UP position).
- Now changeover is executed.
When you want the stand by MP card to return to the active MP, flip the MB switch on
the stand by MP card to OFF (DOWN position), then flip the MB switch on the active
MP card to ON (UP position).
Case2
By System Data Setting:
Assign the following data for changeover.
CME0 Y=6>3600: MM DD HH mm
MM: Month (01-12)
DD : Date (01-31)
HH : Hour (00-23)
mm : Minute (00-59)
NOTE:
After setting the first data, the MAT indicates “INITIAL?_”.
Then input the present time. Now changeover is executed.
When there is no MP card for stand by, or the MB switch on the MP card in stand by is ON (UP
position), the MAT indicates “HARDWARE ERROR”.
BACKUP CPU SYSTEM
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008841 001 ISSUE 5 0 Installation Procedure Manual ...
Страница 24: ... 8 NWA 008841 001 Rev 5 0 90ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 76: ... 60 NWA 008841 001 Rev 5 0 90ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 106: ...CHAPTER 2 INSTALLATION 90 NWA 008841 001 Rev 5 0 90ch2001 fm 5 REMOVE FRONT COVER INSTALLATION OF MAIN EQUIPMENT ...
Страница 148: ...CHAPTER 2 INSTALLATION 132 NWA 008841 001 Rev 5 0 90ch2001 fm Internal Battery Mounting TIE WRAP BATTERY CONNECTION ...