CHAPTER 2 INSTALLATION
SYSTEM INITIALIZATION
There are two methods for System Initialization. The first method is to Clear All Data,
except LEN000 as a CAT terminal, and then program the System Data. The second
method is to use the Resident System Program, which causes the system to configure
itself automatically to the default settings, wherever the line/trunk cards are installed.
NOTE 1:
See CHAPTER 3 for MP switch settings.
Page 292
NOTE 2:
Refer to the “Command Manual” for default settings on the Resident System Program.
All Clear, Except LEN000 CAT
STEP1:
Turn on the “SW1” switch on all the PZ-PW121/PZ-PW126 cards.
- The “ON” lamp must be lit on all the PZ-PW121/PZ-PW126 cards.
STEP2:
On the MP Card, set SW3 to “B” and press SW1.
STEP3:
When the “MN” lamp on the system is lit, set SW3 to the “0” position.
Resident System Program
STEP1:
Mount the line/trunk cards into PIM.
STEP2:
Turn on the “SW1” switch on all the PZ-PW121/PZ-PW126 cards.
- The “ON” lamp must be lit on all the PZ-PW121/PZ-PW126 cards.
STEP3:
On the MP card, set SW3 to “C” and press SW1.
- After 30 to 40 seconds, the “MN” lamp turns on.
- The system has loaded the Resident System Program.
NOTE:
If the “MJ” lamp is lit, repeat Step 3.
STEP4:
On the MP card, set SW3 to the “0” position.
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
SYSTEM INITIALIZATION
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008841 001 ISSUE 5 0 Installation Procedure Manual ...
Страница 24: ... 8 NWA 008841 001 Rev 5 0 90ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 76: ... 60 NWA 008841 001 Rev 5 0 90ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 106: ...CHAPTER 2 INSTALLATION 90 NWA 008841 001 Rev 5 0 90ch2001 fm 5 REMOVE FRONT COVER INSTALLATION OF MAIN EQUIPMENT ...
Страница 148: ...CHAPTER 2 INSTALLATION 132 NWA 008841 001 Rev 5 0 90ch2001 fm Internal Battery Mounting TIE WRAP BATTERY CONNECTION ...