– 426 –
NWA-008841-001 Rev.5.0
90ch3003.fm
NOTE 1:
Set the groove on the switch to the desired position.
NOTE 2:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the
circuit card.
NOTE 3:
Set SW0-1 and SW0-2 as follows:
NOTE 4:
When the PBX is a clock source office, set the SW0-1 and SW0-2 on all the DTI cards mounted
in PIM0 to “OFF”.
NOTE 5:
Mount the DTI card which receives a source clock signal into PIM0.
NOTE 6:
This card must be reset after the SW0-3 to SW0-7 switch settings. Set the MB switch to UP and
then DOWN.
CONDITIONS
DTI0
DTI1
DTI2
· · · · ·
DTI7
REMARKS
SW
0-1
SW
0-2
SW
0-1
SW
0-2
SW
0-1
SW
0-2
SW
0-1
SW
0-2
When one DTI is
provided.
ON OFF
–
–
–
–
–
–
MP card will receive the clock
signal from DTI0 at its PLO0
input.
When more than one
DTI is provided.
ON OFF OFF ON OFF OFF
OFF OFF
MP card will receive the clock
signal from DTI0 at its PLO0
input, under normal conditions.
Should a clock failure occurs
with DTI0, MP card will auto-
matically switch to the PLO1
input which gets clock from
DTI1.
PN-24DTA-C (DTI)
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008841 001 ISSUE 5 0 Installation Procedure Manual ...
Страница 24: ... 8 NWA 008841 001 Rev 5 0 90ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 76: ... 60 NWA 008841 001 Rev 5 0 90ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 106: ...CHAPTER 2 INSTALLATION 90 NWA 008841 001 Rev 5 0 90ch2001 fm 5 REMOVE FRONT COVER INSTALLATION OF MAIN EQUIPMENT ...
Страница 148: ...CHAPTER 2 INSTALLATION 132 NWA 008841 001 Rev 5 0 90ch2001 fm Internal Battery Mounting TIE WRAP BATTERY CONNECTION ...