– 592 –
NWA-008841-001 Rev.5.0
90ch3004.fm
Switch Settings
The figure in the SWITCH NAME column and the position of
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
NOTE 1:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the
circuit card.
NOTE 2:
When SW1 settings have changed, RST switch must be pushed.
NOTE 3:
Use BIOS Redirect only when assisted by NEC.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
MB (Toggle SW)
NOTE 1
UP
For make-busy
For normal operation
RST (Toggle SW)
NOTE 2
Push when starting up this card, after MB switch is set
to DOWN position.
SW1
(Piano Key SW)
NOTE 2
1
ON
BIOS Redirect Utility (Key board)
NOTE 3
Normal Operation
2
ON
BIOS Redirect Utility (Floppy Drive)
NOTE 3
Normal Operation
3
ON
COM2: Use internal modem for remote
maintenance
OFF
COM2: RS-232C (For local direct con-
nection to maintenance console)
4
Not used
ON
DOWN
4
3
2
1
OFF
ON
OFF
OFF
OFF
JULY/1/2006
PZ-VM00/PZ-VM00-M (VM00)/PZ-VM10-M (VM10)
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008841 001 ISSUE 5 0 Installation Procedure Manual ...
Страница 24: ... 8 NWA 008841 001 Rev 5 0 90ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 76: ... 60 NWA 008841 001 Rev 5 0 90ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 106: ...CHAPTER 2 INSTALLATION 90 NWA 008841 001 Rev 5 0 90ch2001 fm 5 REMOVE FRONT COVER INSTALLATION OF MAIN EQUIPMENT ...
Страница 148: ...CHAPTER 2 INSTALLATION 132 NWA 008841 001 Rev 5 0 90ch2001 fm Internal Battery Mounting TIE WRAP BATTERY CONNECTION ...