CHAPTER 2 INSTALLATION
SYSTEM DATA ENTRY
There are two methods for data entry, using a Customer Administration Terminal (CAT)
or a Maintenance Administration Terminal (MAT).
NOTE:
For assigning system data, refer to the “Command Manual”.
CAT
Any D
term
can be assigned as a CAT through programming. The D
term
can still be used as a regular tele-
phone when it is not in CAT mode. If the system is initialized by “C” (Resident System Program), every
D
term
will be able to go into CAT mode. If the system is initialized by “B” (All Clear), only LEN000 is
assigned as a CAT port (the DLC card must be installed in slot LT00).
To use a D
term
as a CAT, follow the procedures shown below.
NOTE:
It is necessary to complete Steps 1 through 6 within 4 seconds.
To set CAT mode:
1.
Press
or
2.
Press
or
-
CNF/Conf lamp flashes
3.
Press
-
CNF/Conf lamp is off
4.
Press
or
5.
Press
or
-
CNF/Conf lamp flashes
6.
Press
-
CNF/Conf, SPKR/Speaker, FNC/Feature lamps are lit
-
“CAT MODE” is displayed on the LCD
7.
Press
or
-
“COMMAND = -” is displayed on the LCD
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
TRF
Transfer
CNF
Conf
*
TRF
Transfer
CNF
Conf
#
LNR/SPD
Redial
SYSTEM DATA ENTRY
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008841 001 ISSUE 5 0 Installation Procedure Manual ...
Страница 24: ... 8 NWA 008841 001 Rev 5 0 90ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 76: ... 60 NWA 008841 001 Rev 5 0 90ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 106: ...CHAPTER 2 INSTALLATION 90 NWA 008841 001 Rev 5 0 90ch2001 fm 5 REMOVE FRONT COVER INSTALLATION OF MAIN EQUIPMENT ...
Страница 148: ...CHAPTER 2 INSTALLATION 132 NWA 008841 001 Rev 5 0 90ch2001 fm Internal Battery Mounting TIE WRAP BATTERY CONNECTION ...