– 455 –
NWA-008841-001 Rev.5.0
90ch3003.fm
NOTE 2:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the
circuit card.
NOTE 3:
Set SW0-1 and SW0-2 as follows:
NOTE 4:
Mount the PRT card which receives a source clock signal into PIM0.
NOTE 5:
This card must be reset after the SW0-3 to SW0-7 switch settings. Set the MB switch to UP and
then DOWN.
NOTE 6:
When using the AP Number 64 to 93 (for AP Number extension) in accommodating the PRT
card on Remote site, be sure to set the SENSE switch and SW1-4 switch of all the PRT cards to
be accommodated to AP Number 31. Also, set AP Number to any one between 64 and 93 by
CM05 for each PRT card. If a different site is used to accommodate the PRT card, be sure to
set switches similarly.
[Series 3800 software or later required]
CONDITIONS
PRT0
PRT1
PRT2
· · · · ·
PRT7
REMARKS
SW
0-1
SW
0-2
SW
0-1
SW
0-2
SW
0-1
SW
0-2
SW
0-1
SW
0-2
When one PRT
is provided.
ON OFF
–
–
–
–
–
–
MP card will receive the
clock signal from PRT0 at
its PLO0 input.
When more than
one PRT is pro-
vided.
ON OFF OFF ON OFF OFF
OFF OFF
MP card will receive the
clock signal from PRT0 at
its PLO0 input, under
normal conditions.
Should a clock failure
occurs with PRT0, MP
card will automatically
switch to the PLO1 input
which gets clock from
PRT1.
NOVEMBER/15/2006
PN-24PRTA (PRT)
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008841 001 ISSUE 5 0 Installation Procedure Manual ...
Страница 24: ... 8 NWA 008841 001 Rev 5 0 90ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 76: ... 60 NWA 008841 001 Rev 5 0 90ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 106: ...CHAPTER 2 INSTALLATION 90 NWA 008841 001 Rev 5 0 90ch2001 fm 5 REMOVE FRONT COVER INSTALLATION OF MAIN EQUIPMENT ...
Страница 148: ...CHAPTER 2 INSTALLATION 132 NWA 008841 001 Rev 5 0 90ch2001 fm Internal Battery Mounting TIE WRAP BATTERY CONNECTION ...