CHAPTER 9 TIMER/COUNTER FUNCTION
287
User’s Manual U15195EJ5V0UD
Figure 9-41. Interrupt Generation Timing in PWM Mode 2 (Sawtooth Wave)
(a) When count clock = f
CLK
0002H
0001H 0002H 0000H 0001H 0002H 0000H 0001H 0002H 0000H 0001H 0002H 0000H 0001H 0002H 0000H 0001H 0002H 0000H 0001H 0002H
CM0nx
TM0n
INTCM0nx
f
CLK
(b) When count clock = f
CLK
/4
0002H
0000H
0001H
0002H
0000H
0001H
CM0nx
TM0n
INTCM0nx
f
CLK
Cautions 1. INTCM0nx is generated at the next f
CLK
after detection of a TM0n and CM0nx match.
2. INTCM0nx is generated at the next f
CLK
after detection of a TM0n and CM0nx match even
if the count clock is 1/2, 1/8, 1/16, or 1/32.
Remarks 1.
n = 0, 1
2.
Where n = 0: x = 3 to 5
Where n = 1: x = 0 to 5
3.
f
CLK
: Base clock
Содержание PD703114