CHAPTER 10 SERIAL INTERFACE FUNCTION
User’s Manual U15195EJ5V0UD
424
(a) Starting procedure
The procedure to start continuous transmission is shown below.
Figure 10-6. Continuous Transmission Starting Procedure
TXD0 (output)
Data (1)
Data (2)
<5>
<1>
<2>
<4>
INTST0 (output)
TXB0 register
FFH
FFH
Data (1)
Data (2)
Data (3)
Data (1)
Data (2)
Data (3)
<3>
ASIF0 register
(TXBF0, TXSF0 bits)
00
11
Note
11
01
01
11
01
11
TXS0 register
Start
bit
Stop
bit
Stop
bit
Start
bit
10
Note
Refer
to
10.2.7 Cautions (2)
.
ASIF0 Register
Transmission Starting Procedure
Internal Operation
TXBF0 TXSF0
•
Set transmission mode
<1> Start transmission unit
0
0
•
Write data (1)
1
0
<2> Generate start bit
•
Read ASIF0 register (confirm that TXBF0 bit = 0)
Start data (1) transmission
1
0
0
0
1
Note
1
1
1
•
Write data (2)
<<Transmission in progress>>
1 1
<3> INTST0 interrupt occurs
•
Read ASIF0 register (confirm that TXBF0 bit = 0)
0
0
1
1
•
Write data (3)
<4> Generate start bit
Start data (2) transmission
<<Transmission in progress>>
1 1
<5> INTST0 interrupt occurs
•
Read ASIF0 register (confirm that TXBF0 bit = 0)
0
0
1
1
•
Write data (4)
1
1
Note
Refer
to
10.2.7 Cautions (2)
.