CHAPTER 9 TIMER/COUNTER FUNCTION
207
User’s Manual U15195EJ5V0UD
(2/4)
Bit position
Bit name
Function
13 to 11
CUL02 to CUL00
Cautions 1. The INTTM0n and INTCM0n3 interrupts can be culled at the same
culling ratio (1/1, 1/2, 1/4, 1/8, 1/16).
2. Even when BFTE3 = 1, BFTEN = 1 (settings to transfer data from
the BFCMn0 to BFCMn3 registers to the CM0n0 to CM0n3
registers), transfer is not performed at the generation timing of
the culled INTTM0n and INTCM0n3 interrupts if MBFTE = 0.
3. If the culling ratio is changed during a count operation, the new
culling ratio is applied after an interrupt has occurred at the
culling ratio prior to the change (see Figure 9-5)
.
4. The INTCM010 to INTCM012, INTCM0n4, and INTCM0n5
interrupts are not affected by the CUL02 to CUL00 bits (the
interrupts occur each time at the same culling ratio as when
CUL02 to CUL00 = 000 (1/1)).
Specifies the count clock for TM0n.
PRM02 PRM01 PRM00
Count
clock
0 0 0
f
CLK
0 0 1
f
CLK
/2
0 1 0
f
CLK
/4
0 1 1
f
CLK
/8
1 0 0
f
CLK
/16
1 0 1
f
CLK
/32
Other than above
Setting prohibited
10 to 8
PRM02 to PRM00
Caution The division ratio switch timing is from when the TM0n value has
become 0000H and the INTTM0n interrupt has occurred. Therefore,
the division ratio is not switched at the timing that corresponds to
interrupt culling.
Remark
For the base clock (f
CLK
), see
9.1.5 (1) Timer 0 clock selection register
(PRM01)
.
5
TM0CEDn
Specifies the operation of the DTMn0 to DTMn2 timers..
0: DTMn0 to DTMn2 perform count operation
1: DTMn0 to DTMn2 stopped
Cautions 1.
Changing the TM0CEDn bit during TM0n operation (TM0CEn = 1)
is prohibited.
2.
If TM0n is operated when TM0CEDn = 1, a signal without dead
time is output to the TO0n0 to TO0n5 pins.
Remark
n = 0, 1