CHAPTER 9 TIMER/COUNTER FUNCTION
251
User’s Manual U15195EJ5V0UD
(b) When BFCMnx > CM0n3 is set in software processing started by INTTM0n
Figure 9-23. Operation Timing in PWM Mode 1 (Asymmetric Triangular Wave, BFCMnx > CM0n3) (1/2)
(a) Operation timing of compare registers 0n0 to 0n2 (CM0n0 to CM0n2)
t
CM0n3
CM0n3
a
CM0nx
match
INTTM0n
INTTM0n
TM0n
count value
Positive phase
(TO0n0, TO0n2, TO0n4)
Negative phase
(TO0n1, TO0n3, TO0n5)
BFCMnx
DTMnx
F/F
Interrupt request
CM0nx
0000H
b
b
b
b
a
b
a
b
b
b
INTCM0n3
INTCM01x
INTCM0n3
Remarks 1.
n = 0, 1
2.
x = 0 to 2
3.
b > CM0n3
4.
t: Dead time = (DTRRn + 1)/f
CLK
(f
CLK
: Base clock)
5.
The above figure shows an active-high case.
6.
INTCM01x is generated on a match between TM01 and CM01x (a in the above figure).
INTCM00x is not generated.
Содержание PD703114
Страница 2: ...2 User s Manual U15195EJ5V0UD MEMO ...