![Moeller DV6-340 Series Скачать руководство пользователя страница 77](http://html.mh-extra.com/html/moeller/dv6-340-series/dv6-340-series_manual_1819311077.webp)
Programming the control
signal terminals
01/02 AWB8230-1415GB
74
Second time ramp 2CH
If the digital input configured as 2CH is active, the motor is acce-
lerated or braked with the second acceleration or deceleration
time. If the 2CH input is deactivated again, a changeover to the
first acceleration/deceleration time takes place.
X
Under PNU A092 and PNU A093, set the required value for the
second acceleration and deceleration time.
X
Then, set PNU A094 to 00 so that the changeover to the second
acceleration and deceleration time through the 2CH input is
enabled (this is the default setting).
X
Program one of the digital inputs 1 to 8 as 2CH, by setting the
corresponding PNU (C001 to C008) to 09.
By default, 2CH is assigned to digital input 5.
Figure 60:
Digital input 3 configured as 2CH (second time ramp)
2CH
FWD
P24
1
3
Figure 61:
Function chart for 2CH (second acceleration time)
f
o
: Output frequency
a
First acceleration time
b
Second acceleration time
FWD/REV
2CH
a
b
f
O
PNU
Name
Adjustable in RUN mode
Value
Function
WE
Normal
Extended
A092
A292
A392
Second accele-
ration time
j
j
0.01 to 3600 s
Setting times for the second acceleration and deceleration
time
15
A093
A293
A393
Second decele-
ration time
A094
A294
Changeover
from the first to
the second
time ramp
–
–
00
Changeover to the second time ramp if an active signal is
present at a 2CH digital input.
00
01
Changeover to the second time ramp when the frequencies
entered in PNU A095 and/or A096 are reached
h
If you set PNU A094 to 01, the changeover to the second
acceleration or deceleration time can take place auto-
matically at the frequency set under PNU A095 or A096
(
a
Section “Time ramps“, Page 148).
h
The value for the first acceleration and deceleration time
is defined in PNU F001 and F002 (
a
Section “Accelera-
tion time 1“, Page 121).
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616