![Moeller DV6-340 Series Скачать руководство пользователя страница 210](http://html.mh-extra.com/html/moeller/dv6-340-series/dv6-340-series_manual_1819311210.webp)
01/02 AWB8230-1415GB
Standard form for user defined
parameter settings
207
b123
Waiting time before stop
[s]
0.00
170
b124
Waiting time to brake confirmation
[s]
0.00
170
b125
Brake enable frequency
[Hz]
0.00
170
b126
Brake enable current
[A]
I
e
170
PNU
Function
Units
Default
Page
Setpoint
PNU
Function
Units
Default
Page
Setpoint
C001
Function of digital input 1
• 01: REV, anticlockwise operation
• 02: FF1, first fixed frequency input
• 03: FF2, second fixed frequency input
• 04: FF3, third fixed frequency input
• 05: FF4, fourth fixed frequency input
• 06: JOG, jog mode
• 07: DB, DC braking
• 08: SET, second parameter set
• 09: 2CH, second time ramp
• 11: FRS, controller inhibit
• 12: EXT, external fault
• 13: USP, unattended start protection
• 14: CS, heavy mains starting
• 15: SFT, parameter protection
• 16: AT, Analog input selection
• 17: SET3, third parameter set
• 18: RST, reset
• 20: STA, three-wire control start signal
• 21: STP, three-wire control stop signal
• 22: STA, three-wire control direction
• 23: PID, activate PID control
• 24: PIDC, reset I component of PID control
• 26: CAS, tacho-generator with vector control
• 27: UP, remote access/acceleration
• 28: DWN, remote access/deceleration
• 31: OPE, setpoint through keypad
• 32 to 38: Bitwise fixed frequencies
• 39: OLR, change over current limit
• 40: Torque limitation active
• 41: TRQ1, torque limitation 1 active
• 42: TRQ2, torque limitation 2 active
• 43: PPI, PI to P control changeover
• 44: BOK, brake enable confirmation
• 45: ORT, direction of rotation
• 46: LAC, ramp function Off
• 47: PCLR, delete positioning deviation
• 48: STAT, setpoint definition through optional
module
• NO: No function
18
66
C002
Function of digital input 2 (values
a
PNU C001)
16
66
C003
Function of digital input 3 (values
a
PNU C001)
06
66
C004
Function of digital input 4 (values
a
PNU C001)
11
66
C005
Function of digital input 5 (values
a
PNU C001)
09
66
C006
Function of digital input 6 (values
a
PNU C001)
03
66
C007
Function of digital input 7 (values
a
PNU C001)
02
66
C008
Function of digital input 8 (values
a
PNU C001)
01
66
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616