01/02 AWB8230-1415GB
Programmable digital inputs
1 to 8
67
You can optionally configure the digital inputs as break (NC)
contacts. To do this, enter 01 under PNU C011 to C018 (corres-
ponding to digital inputs 1 to 8). An exception applies to the RST
input (reset), which can only be operated as a make (NO) contact.
FW is configured as a make (NO) contact under PNU C019.
Table 12:
Configuring digital inputs as break contacts
40
TL
Torque limitation active
94
41
TRQ1
Bitwise control of the torque
limits PNU b041 to b044
94
41
TRQ2
94
43
PPI
P or PI control
98
44
BOK
Confirmation of brake enable
signal
100
45
ORT
Direction of rotation
–
1)
46
LAC
Ramp function off
–
1)
47
PCLR
Erase positioning deviation
–
1)
48
STAT
Setpoint input through optional
module
–
2)
no
NO
No function
–
1)
a
Manual AWB8240-1431.. for encoder module DE6-IOM-ENC
2)
a
Manual for the optional module
Value
Function
Description
a
Page
Caution!
If you reconfigure digital inputs configured as FW or REV
as break contacts (the default setting is as a make
contact), the motor starts immediately. They should not
be reconfigured as break contacts unless this is unavoi-
dable.
PNU
Terminal
Value
Adjustable in RUN mode
Function
WE
Normal
Extended
C011
1
00 or 01
–
j
00: Make contact
01: Break contact
00
C012
2
C013
3
C014
4
C015
5
C016
6
C017
7
C018
8
C019