Programming the control
signal terminals
01/02 AWB8230-1415GB
110
Torque exceeded (OTQ)
When the torque limits set under PNU C055 to C058 are reached
or exceeded, the DV6 frequency inverter activates the digital
output configured as OTQ.
This function is available only in vector control mode (
a
Section
“Voltage/frequency characteristic and voltage boost“, Page 126):
• SLV (sensorless vector) control
• 0 Hz SLV control
• Vector control with optional DE6-IOM-ENC module
X
Program one of the digital outputs 11 to 15 as OTQ by entering
the value 07 in the corresponding PNU (C021 to C025) or under
PNU C026 for signalling relay contacts K11-K12.
By default, OTQ is assigned to digital output 14.
Figure 112: Digital output 11 configured as OTQ (torque exceeded)
24 V
50 mA
11
OTQ
12
CM2
–
+
Figure 113: Function chart for OTQ (torque exceeded)
OTQ
t
PNU C055-
PNU C058
M
PNU
Name
Adjustable in RUN mode
Value
Function
WE
Normal
Extended
C055
Torque threshold (clockwise,
drive mode)
–
j
0 to 200 %
To DV6-340-55k
100
0 to 180 %
From DV6-340-75K
C056
Torque threshold (anticlockwise,
regenerative mode)
0 to 200 %
To DV6-340-55k
0 to 180 %
From DV6-340-75K
C057
Torque threshold (anticlockwise,
drive mode)
0 to 200 %
To DV6-340-55k
0 to 180 %
From DV6-340-75K
C058
Torque threshold (clockwise,
regenerative mode)
0 to 200 %
To DV6-340-55k
0 to 180 %
From DV6-340-75K