01/02 AWB8230-1415GB
Technical Data
187
Outputs
Digital signalling outputs programmable
as
• RUN: Motor operational
• FA1/FA2: Frequency reached/exceeded
• FA3/FA4/FA5: Frequency reached (1)/frequency exceeded (2)/frequency reached (2)
• OD: PID deviation exceeded
• OL: Overload
• AL: Fault
• QTQ: Torque reached/exceeded
• IP: Mains failure
• UV: Undervoltage
• TRQ: Torque limitation
• RNT: Running time exceeded
• ONT: Mains On time exceeded
• THM: Motor thermal overload
• BRK: Enable signal for external brake
• BER: Brake fault
• ZS: Zero speed (only with optional DE6-IOM-ENC module)
• DSE: Speed deviation exceeded (only with optional DE6-IOM-ENC module)
• POK: Positioning (only with optional DE6-IOM-ENC module)
• OL2: Overload alarm 2
Analog outputs
• Frequency output:
I
F
1.2 mA, pulse-width modulated signal (PWM)
• Voltage output: 0 to 10 V
H
,
I
F
2 mA
• Current output: 4 to 20 mA, load impedance 250
O
The following variables can be output:
• Output frequency, PWM
• Output current
• Torque (only SLV control, vector control and 0 Hz SLV control)
• Output frequency, frequency-modulated (terminal FM only)
• Output voltage
• Power consumption
• Thermal load ratio
• Ramp frequency
Signalling relay
Relay contact as a two-way switch; relay energized with a fault
Further features (excerpt)
• Autotuning
• Automatic voltage regulation
• Unattended start protection
• Variable amplification and output voltage reduction
• Frequency jumps
• Minimum/maximum frequency limitation
• Output frequency display
• Fault history register available
• Freely selectable pulse frequency: 0.5 to 15 kHz
• PID control
• Automatic torque boost
• On/OFF fan control
• Second and third parameter set selectable
• Vector control
– SLV (sensorless vector) control
– 0 Hz SLV control
– Vector with feedback (only with optional DE6-IOM-ENC module)
Safety features
• Overcurrent
• Overvoltage
• Undervoltage
• Overtemperature
• Ground fault
• Overload
• Electronic motor protection
• Current transformer fault
• Dynamic braking function (regenerative)
DV6-340-...
075
1K5
2K2
4K0
5K5
7K5
11K
15K
18K5
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616