![Moeller DV6-340 Series Скачать руководство пользователя страница 152](http://html.mh-extra.com/html/moeller/dv6-340-series/dv6-340-series_manual_1819311152.webp)
01/02 AWB8230-1415GB
Acceleration and deceleration
characteristics
149
Acceleration and deceleration characteristics
Under PNU A097, define the characteristic of the acceleration
ramp. This applies to the first and second time ramp. You can
choose between four options (
a
Fig. 146):
• Linear acceleration, value 00 (default)
• S-curve characteristic for acceleration, value 01
• U-curve characteristic for acceleration, value 02
• Inverted U-curve characteristic for acceleration, value 03
Under PNU A098, define the characteristic of the deceleration
ramp in the same way as for acceleration (
a
Fig. 147):
• Linear deceleration, value 00 (default)
• S-curve characteristic for deceleration, value 01
• U-curve characteristic for deceleration, value 02
• Inverted U-curve characteristic for deceleration, value 03
In addition, you can define the curvature of the S- and U-curve
characteristics. Ten values are available for this purpose. Value 01
means the smallest curvature, value 10 the greatest
(
a
Fig. 148). PNU A131 contains the curvature for acceleration,
PNU A132 the curvature for deceleration.
Figure 146: Acceleration characteristics
Figure 147: Deceleration characteristics
00
01
f
t
03
02
f
t
00
01
f
t
03
02
f
t
Figure 148: Curvature of the S- and U-curve characteristics
25
50
75
100
t
PNU A004, 100
PNU F002
96.9
82.4
17.6
3.1
[%]
[%]
f
10
02
99.6
PNU A004, 100
93.8
87.5
68.4
64.6
35.0
25
50
75
100
PNU F002
t
[%]
[%]
f
10
02
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616