Setting Parameters
01/02 AWB8230-1415GB
150
PNU
Name
Adjustable in RUN mode
Value
Function
WE
Normal
Extended
A097
Acceleration
characteristic
–
–
00
Linear acceleration of the motor at the first and second time
ramps
00
01
S-curve characteristic for acceleration of the motor at the
first and second time ramps
02
U-curve characteristic for acceleration of the motor at the
first and second time ramps
03
Inverted U-curve characteristic for acceleration of the motor
at the first and second time ramps
A098
Deceleration
characteristic
–
–
00
Linear deceleration of the motor at the first and second time
ramps
00
01
S-curve characteristic for deceleration of the motor at the
first and second time ramps
02
U-curve characteristic for deceleration of the motor at the
first and second time ramps
03
Inverted U-curve characteristic for deceleration of the motor
at the first and second time ramps
A131
Curvature of
acceleration
characteristic
–
j
01
Smallest curvature of the acceleration ramp
02
...
10
Largest curvature of the acceleration ramp
A132
Curvature of
deceleration
characteristic
–
j
01
Smallest curvature of the deceleration ramp
02
...
10
Largest curvature of the deceleration ramp
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616