4. STARTUP
4 - 12
4.5.1 Test operation mode in MR Configurator2
POINT
When the test operation mode is selected with the slide switches (SW1-1 and
SW1-2), the servo amplifier will not receive commands from the master station
(controller).
(1) Test operation mode
(a) Jog operation
Jog operation can be performed without the master station (controller). Use this operation with the
forced stop reset. This operation may be used independently of whether servo-on or servo-off and
whether a master station (controller) is connected or not.
Operate on the jog operation screen of MR Configurator2.
1) Operation pattern
Item
Initial value
Setting range
Servo motor speed [r/min]
200
0 to Maximum speed
Accel./decel. time constant
[ms]
1000
0 to 50000
2) Operation method
a) The check box "Rotation only while the CCW or CW button is being pushed" is checked.
Operation Screen
operation
Forward rotation start
Keep pressing "Forward CCW".
Reverse rotation start
Keep pressing "Reverse CW".
Stop
Release "Forward CCW" or "Reverse CW".
Forced stop
Click "Forced Stop".
b) The check box "Rotation only while the CCW or CW button is being pushed" is unchecked.
Operation Screen
operation
Forward rotation start
Click "Forward CCW".
Reverse rotation start
Click "Reverse CW".
Stop Click
"Stop".
Forced stop
Click "Forced Stop".
Содержание MR-J4-_GF
Страница 26: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 3 2 4 Mapping data details of link device Refer to chapter 10 ...
Страница 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Страница 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Страница 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Страница 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Страница 271: ...MEMO ...