6. SERVO MOTOR DRIVING
6 - 89
(5) jg mode operation sequence in the indexer method
(a) Station jog operation
The following timing chart shows that a jog operation is started from being stopped at the station No.
0 at servo-on.
Reverse
rotation
0 r/min
Forward
rotation
ON
OFF
ON
OFF
ON
OFF
INP/S_INP
(In-position)
Point actual value
Enabled torque limit value
Controlword bit 4
(Rotation start)
Controlword bit 5
(Direction)
Servo motor speed
Point demand value
1
2
3
5
6
7
7
2
6
5
0
0
4
4 3
(Note 1)
150.00 r/min
Profile velocity
Status DO 5 bit 5
(S_CPO (Rough match))
Status DO 5 bit 6
(S_MEND (Travel completion))
ON
OFF
ON
OFF
(Note 3)
[Pr. PC77]
Positive torque limit value/
Negative torque limit value
[Pr. PC77]
Positive torque limit value/
Negative torque limit value
[Pr. PC77]
Positive torque limit value/
Negative torque limit value
[Pr. PC77]
(Note 3)
4
7
4
2
100.00 r/min
(Note 3)
(Note 2)
Note 1. "Controlword bit 4 (Rotation start)" is not received when the rest of command travel distance is other than "0".
2. Switching "Profile velocity" during the servo motor rotation does not enable this.
3.
A delay time can be set with [Pr. PT39].
Содержание MR-J4-_GF
Страница 26: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 3 2 4 Mapping data details of link device Refer to chapter 10 ...
Страница 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Страница 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Страница 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Страница 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Страница 271: ...MEMO ...