6. SERVO MOTOR DRIVING
6 - 43
(3) Details on the OMS bit of Statusword (pt mode)
Bit Symbol
Description
10
(reserved)
The value at reading is undefined.
12
Set-point
acknowledge
0: Positioning completed (wait for next command)
1: Positioning being executed
13 Following
error
0: No following error
1: Following error
Judgment condition for Following error
When the time set with [Pr. PC69 Following error output filtering time] has elapsed with the
number of droop pulses exceeding the setting value of the [Pr. PC67/Pr. PC68 Following
error output level], this bit becomes "1".
6.2.4 Point table setting method with MR Configurator2
(1) Setting procedure
Click "Positioning-data" in the menu bar, and click "Point Table" in the menu.
The following window will be displayed.
(a)
(g)
(f)
(d)
(c)
(m)
(l)
(i)
(h)
(j)
(k)
(e)
(b)