10. OBJECT DICTIONARY
10 - 6
Index
Sub
Index
Name and function
Data
Type
Access
Variable
mapping
Default
Range
Units
EEP-
ROM
Param
eter
2B2E
0
Unit total power consumption
The unit total power consumption is returned.
I32 ro
Possible 80000000h
to
7FFFFFFFh
Wh
2B2F 0 Current
position
The current position is returned. In the indexer
method, the value is fixed to 0.
I32 ro
Possible 80000000h
to
7FFFFFFFh
pos
units
2B30 0 Command
position
The command position is returned. In the indexer
method, the value is fixed to 0.
I32 ro
Possible 80000000h
to
7FFFFFFFh
pos
units
2B31
0
Command remaining distance
The command remaining distance is returned.
I32 ro
Possible 80000000h
to
7FFFFFFFh
pos
units
2B32
0
Point table No./Station position No
Point table No. or station position No. is returned.
I16 ro
Possible
0000h
to
00FFh
2B81
0
Alarm Monitor 1 Cumulative feedback pulses
The cumulative feedback pulses at alarm
occurrence are returned.
I32 ro
Possible 80000000h
to
7FFFFFFFh
pulse
2B82
0
Alarm Monitor 2 Servo motor speed
The servo motor speed at alarm occurrence is
returned.
I32 ro
Possible 80000000h
to
7FFFFFFFh
r/min
mm/s
2B83
0
Alarm Monitor 3 Droop pulses
The droop pulses at alarm occurrence are
returned.
I32 ro
Possible 80000000h
to
7FFFFFFFh
pulse
2B84
0
Alarm Monitor 4 Cumulative command pulses
The cumulative command pulses (encoder unit)
at alarm occurrence are returned.
I32 ro
Possible 80000000h
to
7FFFFFFFh
pulse
2B85
0
Alarm Monitor 5 Command pulse frequency
The command pulse frequency at alarm
occurrence is returned.
I32 ro
Possible 80000000h
to
7FFFFFFFh
kpulse/
s
2B88
0
Alarm Monitor 8 Regenerative load ratio
The regenerative load ratio at alarm occurrence is
returned.
U16 ro
Possible
0000h
to
FFFFh
%
2B89
0
Alarm Monitor 9 Effective load ratio
The effective load ratio at alarm occurrence is
returned.
U16 ro
Possible
0000h
to
FFFFh
%
2B8A
0
Alarm Monitor 10 Peak load ratio
The peak load ratio at alarm occurrence is
returned.
U16 ro
Possible
0000h
to
FFFFh
%
2B8B
0
Alarm Monitor 11 Instantaneous torque
The instantaneous torque at alarm occurrence is
returned.
I16 ro
Possible
8000h
to
7FFFh
%
2B8C
0
Alarm Monitor 12 Within one-revolution position
The position within one-revolution at alarm
occurrence is returned.
I32 ro
Possible 80000000h
to
7FFFFFFFh
pulse
2B8D
0
Alarm Monitor 13 ABS counter
The ABS counter at alarm occurrence is returned.
I32 ro
Possible 80000000h
to
7FFFFFFFh
rev
2B8E
0
Alarm Monitor 14 Load to motor inertia ratio
The load to motor inertia ratio at alarm
occurrence is returned.
U16 ro
Possible
0000h
to
FFFFh
0.01
times
2B8F
0
Alarm Monitor 15 Bus voltage
The bus voltage at alarm occurrence is returned.
I32 ro
Possible
0000h
to
FFFFh
V
2B90
0
Alarm Monitor 16 Load-side cumulative feedback
pulses
The load-side cumulative feedback pulses at
alarm occurrence are returned.
I32 ro
Possible 80000000h
to
7FFFFFFFh
pulse
2B91
0
Alarm Monitor 17 Load-side droop pulses
The load-side droop pulses at alarm occurrence
are returned.
I32 ro
Possible 80000000h
to
7FFFFFFFh
pulse
2B92
0
Alarm Monitor 18 Load-side encoder information
1 Z-phase counter
The load-side encoder information 1 at alarm
occurrence is returned.
I32 ro
Possible 80000000h
to
7FFFFFFFh
pulse
Содержание MR-J4-_GF
Страница 26: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 3 2 4 Mapping data details of link device Refer to chapter 10 ...
Страница 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Страница 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Страница 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Страница 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Страница 271: ...MEMO ...