7. PARAMETERS
7 - 24
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
C
P
P
S
PT49
STA
Acceleration
time constant
Set the acceleration time taken from 0 r/min (0 mm/s) to the rated speed for the
command.
If the servo motor is started with a value exceeding 20000 ms, [AL. F4] will occur, and the
servo motor will not operate.
If the preset speed command
is lower than the rated speed,
acceleration/deceleration time
will be shorter.
Time
[Pr. PT50] setting
0 r/min
(0 mm/s)
Rated
speed
Servo motor speed
[Pr. PT49] setting
For example for the servo motor of 3000 r/min rated speed, set 3000 (3 s) to increase
speed from 0 r/min to 1000 r/min in 1 s.
Setting range: 0 to 50000
0
[ms]
PT50
STB
Deceleration
time constant
Set the deceleration time taken from the rated speed to 0 r/min (0 mm/s) for the
command.
If the servo motor is started with a value exceeding 20000 ms, [AL. F4] will occur, and the
servo motor will not operate.
When the servo motor is started with a value exceeding 2000 ms in the indexer mode,
the deceleration time constant is clamped to 20000 ms.
Setting range: 0 to 50000
0
[ms]