7. PARAMETERS
7 - 23
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
C
P
P
S
PT45
HMM
Home
position
return types
Setting
value
Home position
return direction
Home position
return method
Setting
value
Home position
return direction
Home position
return method
3
Address
increasing
direction
Method 3
21
Address
decreasing
direction
Method 21
4
Address
increasing
direction
Method 4
22
Address
decreasing
direction
Method 22
5
Address
decreasing
direction
Method 5
23
Address
increasing
direction
Method 23
6
Address
decreasing
direction
Method 6
24
Address
increasing
direction
Method 24
7
Address
increasing
direction
Method 7
27
Address
decreasing
direction
Method 27
8
Address
increasing
direction
Method 8
28
Address
decreasing
direction
Method 28
11
Address
decreasing
direction
Method 11
33
Address
decreasing
direction
Method 33
12
Address
decreasing
direction
Method 12
34
Address
increasing
direction
Method 34
19
Address
increasing
direction
Method 19
35
Method 35
20
Address
increasing
direction
Method 20
37
Method 37
Note. Torque limit changing dog type and torque limit changing data set type are available only in the
indexer method.
Содержание MR-J4-_GF
Страница 26: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 3 2 4 Mapping data details of link device Refer to chapter 10 ...
Страница 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Страница 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Страница 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Страница 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Страница 271: ...MEMO ...